Comments on Draft submitted to MDE
You will need Adobe Acrobat to read the documents - go here
to get a copy
gpd = gallons per day.
Comparison Table:
| |
1st Draft |
2nd Draft |
Draft to MDE |
Notes |
| Baseline Average Flow |
373,500 gpd |
340,000 gpd |
340,000 gpd |
|
| Remaining Flow |
127,000 gpd |
160,000 gpd |
160,000 gpd |
|
| -
Flow due to outstanding permits |
30,500 gpd |
12,500 gpd |
12,500 gpd |
= 72 units connected since 1st draft |
| =
Available Flow |
96,500 gpd |
147,500 gpd |
147,500 gpd |
|
| -
Wet Weather Reserve |
16,500 gpd (3.3%) |
20,000 gpd (4%) |
20,000 gpd (4%) |
% of total plant capacity (500,000 gpd) |
| |
|
|
|
|
| /2
= Available 1st Year |
40,000 gpd |
63,750 gpd |
63,750 gpd |
|
| Institutional |
2,000 gpd (5%) |
2,000 gpd (3.1%) |
2,000 gpd (3.1%) |
1,250 already committed for Hospice Facility |
| Commercial/Industrial |
8,000 gpd (20%) |
15,000 gpd (23.5%) |
23,750 gpd (37.3%) |
5,270 already committed first year |
| Residential Infill |
1,000 gpd (2.5%) |
5,500 gpd (8.6%) |
5,500 gpd (8.6%) |
|
| Other developments |
3,000 gpd (7.5%) |
included as infill above |
included as infill above |
|
| Northbrook/Symphony Village |
26,000 gpd (65%) |
41,250 gpd (64.7%) |
32,500 gpd (51.0%) |
|
See Sec ID (Page 6): The plan still requires a new allocation
even if the change in use results in fewer gpd of use. This does nothing
to encourage commercial development that results in lower usage.
See Sec IV (Page11): The plan names the Town Manager as the
controlling authority and the Town Council as the approving authority for the
first year of the plan.
Here are the first and second
drafts,